P_2x4T_028_C-1

Production testing

Date:2/15/2007

Operator: Gino Bolla

start testing time:9:49 AM

Sensor: S_2x4T_02, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0XE4K3KT30B
ROC1XE4K3KT29B
ROC2XE4K3KT30C
ROC3XE4K3KT31D
ROC4XE4K3KT30A
ROC5XE4K3KT39D
ROC6XE4K3KT39C
ROC7XE4K3KT31B

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 122 140 140 134 134 134 142 150
Vana, VanaData 112 124 131 130 125 143 141 157
TestDdata ,TestD Plots010002100
LightData ,Light Plots05000000
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD

Comment (if any):

This Device have been tested 1Times prior to this one and here are the links to the previous tests:

P_2x4T_028_C.html,

End testing time: 9:58 AM