Sensor: S_2x3T_18, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | W28_X54K5TT | 27A |
ROC1 | W28_X54K5TT | 26D |
ROC2 | W28_X54K5TT | 26B |
ROC3 | W29_X64K5ST | 64C |
ROC4 | W29_X64K5ST | 64D |
ROC5 | W29_X64K5ST | 65B |
Ibias_DAC, Ibias_DAC Data | 140 | 128 | 142 | 132 | 146 | 138 |
Vana, VanaData | 134 | 131 | 141 | 140 | 135 | 138 | FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
TestDdata ,TestD Plots | 0 | 0 | 2 | 0 | 0 | 0 |
LightData ,Light Plots | 0 | 0 | 0 | 0 | 0 | 0 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any): Good.
This Device have been tested 2Times prior to this one and here are the links to the previous tests:End testing time: 4:45 PM