Sensor: S_2x3T_01, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | XE4K3KT | 22B |
ROC1 | XE4K3KT | 23A |
ROC2 | XE4K3KT | 23B |
ROC3 | XE4K3KT | 25A |
ROC4 | XE4K3KT | 24B |
ROC5 | XE4K3KT | 24A |
Ibias_DAC, Ibias_DAC Data | 130 | 126 | 130 | 130 | 140 | 128 |
Vana, VanaData | 126 | 118 | 123 | 137 | 129 | 138 | FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
TestDdata ,TestD Plots | 0 | 2 | 0 | 0 | 2 | 2 |
LightData ,Light Plots | 0 | 0 | 2 | 0 | 0 | 0 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any):
This Device have been tested 1Times prior to this one and here are the links to the previous tests:End testing time: 10:04 AM