P_2x3B_157_A-1

Production testing

Date:1/17/2007

Operator: Gino Bolla

start testing time:10:30 AM

Sensor: S_2x3B_15, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W21_XA4KFIT36A
ROC1W21_XA4KFIT35D
ROC2W21_XA4KFIT35C
ROC3W21_XA4KFIT17A
ROC4W21_XA4KFIT11C
ROC5W21_XA4KFIT11D

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 126 140 142 114 134 120
Vana, VanaData 128 120 141 116 135 131
TestDdata ,TestD Plots001000
LightData ,Light Plots000000
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD GOOD

Comment (if any): GOOD

This Device have been tested 1Times prior to this one and here are the links to the previous tests:

P_2x3B_157_A.html,

End testing time: 10:35 AM