Sensor: S_2x3B_13, Data for leakage current measurement , and plot on overall it is a GOOD sensor
| ROC | ROC wafer | Label |
|---|---|---|
| ROC0 | XE4KFET | 31D |
| ROC1 | XE4KFET | 23D |
| ROC2 | XE4KFET | 24C |
| ROC3 | XE4KFET | 26A |
| ROC4 | XE4KFET | 26B |
| ROC5 | XE4KFET | 28B |
| Ibias_DAC, Ibias_DAC Data | 128 | 128 | 140 | 132 | 144 | 138 |
| Vana, VanaData | 125 | 115 | 144 | 143 | 139 | 134 | FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
| TestDdata ,TestD Plots | 2 | 0 | 0 | 1 | 2 | 0 |
| LightData ,Light Plots | 5 | 6 | 5 | 7 | 6 | 6 |
| Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
| Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any): Light test got significantly worse. Retesting.
This Device have been tested 1Times prior to this one and here are the links to the previous tests:End testing time: 3:17 PM