P_2x3B_104_A-1

Production testing

Date:2/19/2007

Operator: Gino Bolla

start testing time:3:34 PM

Sensor: S_2x3B_10, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W33_XC4K5LT58A
ROC1W33_XC4K5LT57D
ROC2W33_XC4K5LT57C
ROC3W33_XC4K5LT34C
ROC4W33_XC4K5LT34D
ROC5W33_XC4K5LT35B

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 150 132 138 138 140 144
Vana, VanaData 131 130 145 138 124 132
TestDdata ,TestD Plots000100
LightData ,Light Plots000000
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD GOOD

Comment (if any):

This Device have been tested 1Times prior to this one and here are the links to the previous tests:

P_2x3B_104_A.html,

End testing time: 3:39 PM