P_1x5R_156_A-5

Production testing

Date:5/22/2007

Operator: Gino Bolla

start testing time:4:33 PM

Sensor: S_1x5R_15, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W28_X54K5TT63B
ROC1W28_X54K5TT63A
ROC2W28_X54K5TT62C
ROC3W28_X54K5TT62B
ROC4W28_X54K5TT62A

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 134 138 126 146 152
Vana, VanaData 132 132 131 127 139
TestDdata ,TestD Plots40921991402271683
LightData ,Light Plots41500003
Pass/Fail TestD BAD BAD BAD BAD BAD
Pass/Fail LIGHT BAD GOOD GOOD GOOD GOOD

Comment (if any):

This Device have been tested 5Times prior to this one and here are the links to the previous tests:

P_1x5R_156_A-1.html,

P_1x5R_156_A-2.html,

P_1x5R_156_A-3.html,

P_1x5R_156_A-4.html,

P_1x5R_156_A.html,

End testing time: 4:38 PM