Sensor: S_1x5L_11, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | W30_X74K5RT | 37D |
ROC1 | W30_X74K5RT | 37C |
ROC2 | W30_X74K5RT | 29D |
ROC3 | W30_X74K5RT | 36D |
ROC4 | W30_X74K5RT | 36C |
Ibias_DAC, Ibias_DAC Data | 132 | 150 | 130 | 140 | 130 |
Vana, VanaData | 115 | 127 | 129 | 135 | 131 | FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
TestDdata ,TestD Plots | 1 | 2 | 0 | 0 | 0 |
LightData ,Light Plots | 0 | 0 | 0 | 0 | 0 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD |
Noise MAP
Efficiency MAP
Comment (if any):
This Device have been tested 1Times prior to this one and here are the links to the previous tests:End testing time: 8:16 AM