Sensor: S_1x5L_10, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | W33_XC4K5LT | 57B |
ROC1 | W33_XC4K5LT | 57A |
ROC2 | W33_XC4K5LT | 56C |
ROC3 | W33_XC4K5LT | 56A |
ROC4 | W33_XC4K5LT | 55D |
Ibias_DAC, Ibias_DAC Data | 132 | 140 | 140 | 142 | 140 |
Vana, VanaData | 131 | 141 | 140 | 113 | 127 | FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
TestDdata ,TestD Plots | 0 | 0 | 0 | 2 | 0 |
LightData ,Light Plots | 0 | 0 | 0 | 0 | 0 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any):
This Device have been tested 1Times prior to this one and here are the links to the previous tests:End testing time: 3:09 PM