Sensor: S_1x5L_08, Data for leakage current measurement , and plot on overall it is a GOOD sensor
| ROC | ROC wafer | Label |
|---|---|---|
| ROC0 | W32_XA4K5NT | 56B |
| ROC1 | W32_XA4K5NT | 56A |
| ROC2 | W32_XA4K5NT | 55D |
| ROC3 | W28_X54K5TT | 05C |
| ROC4 | W32_XA4K5NT | 55B |
| Ibias_DAC, Ibias_DAC Data | 140 | 142 | 152 | 140 | 138 |
| Vana, VanaData | 124 | 129 | 132 | 147 | 138 | FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
| TestDdata ,TestD Plots | 0 | 1 | 0 | 1 | 0 |
| LightData ,Light Plots | 0 | 0 | 0 | 0 | 0 |
| Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD |
| Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any): Good.
This Device have been tested 2Times prior to this one and here are the links to the previous tests:End testing time: 3:00 PM