Sensor: S_1x5L_06, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | W29_X64K5ST | 04C |
ROC1 | W29_X64K5ST | 04B |
ROC2 | W29_X64K5ST | 04A |
ROC3 | W29_X64K5ST | 03D |
ROC4 | W29_X64K5ST | 03C |
Ibias_DAC, Ibias_DAC Data | 128 | 132 | 136 | 128 | 122 |
Vana, VanaData | 128 | 122 | 117 | 133 | 120 | FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
TestDdata ,TestD Plots | 0 | 0 | 0 | 0 | 5 |
LightData ,Light Plots | 0 | 0 | 0 | 0 | 1 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any): Good.
This Device have been tested 1Times prior to this one and here are the links to the previous tests:End testing time: 3:17 PM