P_1x2R_182_A-1

Production testing

Date:2/8/2007

Operator: Gino Bolla

start testing time:3:24 PM

Sensor: S_1x2R_18, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W28_X54K5TT11A
ROC1W28_X54K5TT29B

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 124 130
Vana, VanaData 128 128
TestDdata ,TestD Plots11
LightData ,Light Plots00
Pass/Fail TestD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD

Noise MAP

[IMAGE] of

Efficiency MAP

[IMAGE] of

ROC0 NOISE[IMAGE] of [IMAGE] of MEAN = 4.984634

SIGMA = 0.403124
ROC1 NOISE[IMAGE] of [IMAGE] of MEAN = 5.075475

SIGMA = 0.393917

Comment (if any):

This Device have been tested 1Times prior to this one and here are the links to the previous tests:

P_1x2R_182_A.html,

End testing time: 3:35 PM