P_1x2R_038_A-2

Production testing

Date:2/19/2007

Operator: Gino Bolla

start testing time:2:09 PM

Sensor: S_1x2R_03, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W33_XC4K5LT25D
ROC1W33_XC4K5LT25B

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 132 130
Vana, VanaData 117 140
TestDdata ,TestD Plots10
LightData ,Light Plots00
Pass/Fail TestD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD

Comment (if any):

This Device have been tested 2Times prior to this one and here are the links to the previous tests:

P_1x2R_038_A-1.html,

P_1x2R_038_A.html,

End testing time: 2:14 PM