P_1x2L_171_A-2

Production testing

Date:2/9/2007

Operator: Cameron McKinney

start testing time:11:12 AM

Sensor: S_1x2L_17, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W30_X74K5RT25B
ROC1W30_X74K5RT24A

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 136 138
Vana, VanaData 130 134
TestDdata ,TestD Plots00
LightData ,Light Plots00
Pass/Fail TestD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD

Noise MAP

[IMAGE] of

Efficiency MAP

[IMAGE] of

ROC0 NOISE[IMAGE] of [IMAGE] of MEAN = 5.193427

SIGMA = 0.395571
ROC1 NOISE[IMAGE] of [IMAGE] of MEAN = 4.461477

SIGMA = 0.335452

Comment (if any): OK.

This Device have been tested 2Times prior to this one and here are the links to the previous tests:

P_1x2L_171_A-1.html,

P_1x2L_171_A.html,

End testing time: 11:27 AM