Sensor: S_1x2L_17, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | W30_X74K5RT | 25B |
ROC1 | W30_X74K5RT | 24A |
Ibias_DAC, Ibias_DAC Data | 136 | 138 |
Vana, VanaData | 130 | 134 | FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
TestDdata ,TestD Plots | 0 | 0 |
LightData ,Light Plots | 0 | 0 |
Pass/Fail TestD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD |
Noise MAP
Efficiency MAP
ROC0 NOISE | MEAN = 5.193427SIGMA = 0.395571 | ||
ROC1 NOISE | MEAN = 4.461477SIGMA = 0.335452 |
Comment (if any): OK.
This Device have been tested 2Times prior to this one and here are the links to the previous tests:End testing time: 11:27 AM