In-plane thermal conductivity measurement
Experimentalist, Michael Wasem
Date of measurement, 5/29/2023
Apparatus, InPlane
Material, INPL22
Sample, 1
Length (mm), 2.9, 0.05
Width (mm), 50, 0.05
Thickness (mm), 4.11, 0.05
Heater Voltage, 15.01
Cooler Voltage, 0
Hot Fluxmeter Channels, 105, 106, 107, 108, 109, 110
Cold Fluxmeter Channels, 125, 126, 127, 128, 129, 130
Hot Fluxmeter Temperatures (C), 22.9762, 22.074, 21.269, 20.4008, 19.6316, 18.6622
Cold Fluxmeter Temperatures (C), 12.5344, 11.6296, 10.779, 9.94812, 9.09546, 8.14385
Hot Fluxmeter Temperature Uncertainties (C), 0.000987323, 0.0012456, 0.00117532, 0.00105588, 0.0010149, 0.00110749
Cold Fluxmeter Temperature Uncertainties (C), 0.00100272, 0.000817468, 0.00103079, 0.00106165, 0.000853592, 0.000895372
Hot Fluxmeter Temperatures Relative to Hottest Thermistor (C), 0, -0.901908, -1.70712, -2.57541, -3.34428, -4.31368
Cold Fluxmeter Temperatures Relative to Hottest Thermistor (C), 0, -0.904934, -1.75562, -2.58671, -3.4393, -4.39093
Hot Fluxmeter Temperature Relative to Hottest Thermistor Uncertainties (C), 0, 0.00188258, 0.00153623, 0.00149995, 0.00154682, 0.00144718
Cold Fluxmeter Temperature Relative to Hottest Thermistor Uncertainties (C), 0, 0.0017602, 0.00101487, 0.00173882, 0.00133038, 0.00117341

Heater Thermistors
Cooler Thermistors
Heater Thermistors relative to hottest thermistor
Cooler Thermistors relative to the hottest thermistor

Analyst, Michael Wasem
Analysis date, 7/22/2023
Apparatus inter-thermistor distance (mm), 8
Apparatus thermistor bore diameter (mm), 1.27
Apparatus fluxmeter width (mm), 50.8
Apparatus fluxmeter thickness (mm), 6.36
Apparatus fluxmeter conductivity (W/mK), 355
Heater Biases: 0, 0, 0, 0, 0, 0
Cooler Biases: 0, 0, 0, 0, 0, 0
Hot fluxmeter flux (W/m^2), 37763.5 +/- 1433.72
Cold fluxmeter flux (W/m^2), 38543.7 +/- 1463.08
Heat flux through sample (W/m^2), 38153.6 +/- 1096.01
Heat flow through sample (W), 12.327 +/- 0.354107
Temperature at hot end of sample (C), 17.8569 +/- 0.217105
Temperature at cold end of sample (C), 13.3949 +/- 0.105113
deltaT (C), 4.46208 +/- 0.241212
R (K/W), 0.361977, 0.022159
RA (Km^2/W), 7.43862e-05, 4.64333e-06
Hot flux meter fit
Cold flux meter fit

Hot flux meter difference fit
Cold flux meter difference fit