P_2x5_156_A-1

Production testing

Date:2/1/2007

Operator: Isaac Childres

start testing time:3:26 PM

Sensor: S_2x5_156, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W28_X54K5TT74A
ROC1W28_X54K5TT73D
ROC2W28_X54K5TT73C
ROC3W28_X54K5TT73B
ROC4W28_X54K5TT73A
ROC5W28_X54K5TT57C
ROC6W28_X54K5TT57D
ROC7W28_X54K5TT58A
ROC8W28_X54K5TT58B
ROC9W28_X54K5TT58D

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 142 134 146 148 132 142 126 144 146 138
Vana, VanaData 130 129 133 139 132 134 120 137 140 135
TestDdata ,TestD Plots0000000001
LightData ,Light Plots0000000000
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD

Comment (if any): Good.

This Device have been tested 1Times prior to this one and here are the links to the previous tests:

P_2x5_156_A.html,

End testing time: 3:31 PM