P_2x5_149_A

Production testing

Date:1/10/2007

Operator: Gino Bolla

start testing time:10:26 AM

Sensor: S_2x5_149, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W31_X44K5UT53D
ROC1W31_X44K5UT53C
ROC2W31_X44K5UT53B
ROC3W31_X44K5UT52A
ROC4W31_X44K5UT51D
ROC5W31_X44K5UT37A
ROC6W31_X44K5UT37B
ROC7W31_X44K5UT37D
ROC8W31_X44K5UT38A
ROC9W31_X44K5UT38B

Depletion Voltage is -48 and suggested operational voltage is -88
Ibias_DAC, Ibias_DAC Data 130 130 130 144 132 144 142 134 134 140
Vana, VanaData 133 123 139 137 130 145 144 125 127 130
CalDelData and plots898482758574718885100
VthrCompData and plots71808386748582627671
TestDdata ,TestD Plots1000000000
LightData ,Light Plots0000000000
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD

Comment (if any): GOOD

This Device have been tested 0Times prior to this one and here are the links to the previous tests:

End testing time: 10:42 AM