Sensor: S_2x5_149, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | W31_X44K5UT | 53D |
ROC1 | W31_X44K5UT | 53C |
ROC2 | W31_X44K5UT | 53B |
ROC3 | W31_X44K5UT | 52A |
ROC4 | W31_X44K5UT | 51D |
ROC5 | W31_X44K5UT | 37A |
ROC6 | W31_X44K5UT | 37B |
ROC7 | W31_X44K5UT | 37D |
ROC8 | W31_X44K5UT | 38A |
ROC9 | W31_X44K5UT | 38B |
Ibias_DAC, Ibias_DAC Data | 130 | 130 | 130 | 144 | 132 | 144 | 142 | 134 | 134 | 140 |
Vana, VanaData | 133 | 123 | 139 | 137 | 130 | 145 | 144 | 125 | 127 | 130 |
CalDelData and plots | 89 | 84 | 82 | 75 | 85 | 74 | 71 | 88 | 85 | 100 |
VthrCompData and plots | 71 | 80 | 83 | 86 | 74 | 85 | 82 | 62 | 76 | 71 | Depletion Voltage is -48 and suggested operational voltage is -88
TestDdata ,TestD Plots | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
LightData ,Light Plots | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any): GOOD
This Device have been tested 0Times prior to this one and here are the links to the previous tests:End testing time: 10:42 AM