Sensor: S_2x5_147, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | W30_X74K5RT | 67D |
ROC1 | W30_X74K5RT | 67C |
ROC2 | W30_X74K5RT | 67B |
ROC3 | W30_X74K5RT | 67A |
ROC4 | W30_X74K5RT | 66D |
ROC5 | W30_X74K5RT | 45C |
ROC6 | W30_X74K5RT | 45D |
ROC7 | W30_X74K5RT | 46A |
ROC8 | W30_X74K5RT | 46C |
ROC9 | W30_X74K5RT | 46D |
Ibias_DAC, Ibias_DAC Data | 148 | 138 | 154 | 150 | 128 | 138 | 144 | 134 | 136 | 138 |
Vana, VanaData | 139 | 135 | 131 | 127 | 131 | 133 | 130 | 129 | 124 | 134 |
CalDelData and plots | 86 | 85 | 66 | 84 | 89 | 83 | 82 | 83 | 98 | 94 |
VthrCompData and plots | 77 | 83 | 83 | 80 | 64 | 69 | 75 | 71 | 67 | 70 | Depletion Voltage is -48 and suggested operational voltage is -88
TestDdata ,TestD Plots | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 |
LightData ,Light Plots | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any): Borderline high IV, but sending it through.
This Device have been tested 0Times prior to this one and here are the links to the previous tests:End testing time: 12:39 PM