P_2x5_147_A

Production testing

Date:1/26/2007

Operator: Isaac Childres

start testing time:12:18 PM

Sensor: S_2x5_147, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W30_X74K5RT67D
ROC1W30_X74K5RT67C
ROC2W30_X74K5RT67B
ROC3W30_X74K5RT67A
ROC4W30_X74K5RT66D
ROC5W30_X74K5RT45C
ROC6W30_X74K5RT45D
ROC7W30_X74K5RT46A
ROC8W30_X74K5RT46C
ROC9W30_X74K5RT46D

Depletion Voltage is -48 and suggested operational voltage is -88
Ibias_DAC, Ibias_DAC Data 148 138 154 150 128 138 144 134 136 138
Vana, VanaData 139 135 131 127 131 133 130 129 124 134
CalDelData and plots86856684898382839894
VthrCompData and plots77838380646975716770
TestDdata ,TestD Plots0000000100
LightData ,Light Plots0000000000
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD

Comment (if any): Borderline high IV, but sending it through.

This Device have been tested 0Times prior to this one and here are the links to the previous tests:

End testing time: 12:39 PM