Production testing

Date:2/5/2007

Operator: Cameron McKinney

start testing time:4:08 PM

Sensor: S_2x5_099, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W28_X54K5TT34D
ROC1W28_X54K5TT34C
ROC2W28_X54K5TT34A
ROC3W28_X54K5TT33D
ROC4W28_X54K5TT33B
ROC5W28_X54K5TT14D
ROC6W28_X54K5TT15A
ROC7W28_X54K5TT15B
ROC8W28_X54K5TT15C
ROC9W28_X54K5TT15D

Depletion Voltage is -46 and suggested operational voltage is -86
Ibias_DAC, Ibias_DAC Data 144 122 152 134 132 134 140 132 128 134
Vana, VanaData 144 142 143 131 124 128 132 127 137 134
CalDelData and plots77847189828078796688
VthrCompData and plots76757973807677749172
TestDdata ,TestD Plots0000000000
LightData ,Light Plots0000000001
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD

Comment (if any): OK.

This Device have been tested 0Times prior to this one and here are the links to the previous tests:

End testing time: 4:27 PM