P_2x5_079_A-1

Production testing

Date:10/4/2007

Operator: Gino Bolla

start testing time:3:27 PM

Sensor: S_2x5_079, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W13_XX4JPAT25B
ROC1W13_XX4JPAT03D
ROC2W13_XX4JPAT24D
ROC3W13_XX4JPAT24C
ROC4W13_XX4JPAT24B
ROC5W13_XX4JPAT28C
ROC6W13_XX4JPAT28D
ROC7W13_XX4JPAT29B
ROC8W13_XX4JPAT29C
ROC9W13_XX4JPAT11A

This plaquette was reworked. Old results here

Inspected by Arndt Kirk on date 8/20/2007
LR_dev0.019
LL_dev0.018

PLAQUETTE GLUED with FULL PRESSURE

FINAL COMMENT by Arndt KirkNO ASSEMBLY PROBLEMS No wirebonding problems.

PLAQUETTE made READY for ENCAPSULATION on 8/20/2007 by Arndt Kirk

PLAQUETTE encapsulated on 8/21/2007 by Ozhan Koybasi

PLAQUETTE made READY for testing on 8/21/2007 by Ozhan Koybasi

P_2x5_079_Aon 8/23/2007 8:57 AM

Plaq does NOT work. With the HARD reset I can see only the first 7 ROCs. Humongous power consumption on the digital supply. Still The I2C is working well for all ROCs

For now the device stays in testing

Gino Noticed that the capacitor for DV on ROC6 had "way more solder than needed" and suspected a short. The capacitor was removed but the symptoms stay the same.

Inspected by Bolla Gino on date 8/27/2007
PictureComment
[IMAGE] of resoldered the capacitor and symptoms stay the same. Only first 7 ROCs visible in the Aout (as shown in the picture). We are now going to bypass ROC7.