Sensor: S_2x5_066, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | X94KFJT | 66A |
ROC1 | X94KFJT | 56C |
ROC2 | X94KFJT | 46A |
ROC3 | X94KFJT | 36A |
ROC4 | X94KFJT | 36C |
ROC5 | X94KFJT | 26A |
ROC6 | X94KFJT | 26C |
ROC7 | X94KFJT | 05C |
ROC8 | X94KFJT | 05D |
ROC9 | X94KFJT | 64B |
Ibias_DAC, Ibias_DAC Data | 128 | 132 | 146 | 132 | 144 | 142 | 142 | 144 | 138 | 134 |
Vana, VanaData | 127 | 127 | 141 | 131 | 146 | 141 | 150 | 135 | 141 | 143 |
CalDelData and plots | 99 | 71 | 84 | 94 | 72 | 94 | 81 | 88 | 85 | 94 |
VthrCompData and plots | 79 | 80 | 86 | 81 | 78 | 81 | 86 | 79 | 71 | 74 | Depletion Voltage is -50 and suggested operational voltage is -90
TestDdata ,TestD Plots | 1 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 2 | 5 |
LightData ,Light Plots | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 2 | 4 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Noise MAP
Efficiency MAP
EXTRA DACs for NOISE
VHldDe | 130 | 125 | 105 | 125 | 95 | 130 | 90 | 105 | 105 | 95 |
Vsf | 140 | 140 | 140 | 135 | 145 | 145 | 145 | 140 | 140 | 140 |
VoffsetOp | 75 | 60 | 90 | 75 | 95 | 95 | 85 | 80 | 90 | 100 |
VIbias_PH | 100 | 100 | 100 | 100 | 100 | 105 | 100 | 100 | 105 | 100 |
Comment (if any):
This Device have been tested 0Times prior to this one and here are the links to the previous tests:End testing time: 9:50 AM