Sensor: S_2x5_025, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | XE4KFET | 13A |
ROC1 | XE4KFET | 20C |
ROC2 | XE4KFET | 21B |
ROC3 | XE4KFET | 22A |
ROC4 | XE4KFET | 23A |
ROC5 | XE4KFET | 21D |
ROC6 | XE4KFET | 27C |
ROC7 | XE4KFET | 29C |
ROC8 | XE4KFET | 37C |
ROC9 | XE4KFET | 22C |
Ibias_DAC, Ibias_DAC Data | 140 | 142 | 144 | 126 | 132 | 124 | 138 | 144 | 144 | 150 |
Vana, VanaData | 130 | 140 | 148 | 109 | 132 | 135 | 137 | 128 | 144 | 144 | FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
TestDdata ,TestD Plots | 0 | 1 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 1 |
LightData ,Light Plots | 1 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 1 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any): Okay.
This Device have been tested 1Times prior to this one and here are the links to the previous tests:End testing time: 11:41 AM