Date:1/24/2007

Operator: Isaac Childres

start testing time:11:44 AM

Sensor: S_2x4T_17, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W28_X54K5TT52D
ROC1W28_X54K5TT52B
ROC2W28_X54K5TT52A
ROC3W28_X54K5TT51D
ROC4W28_X54K5TT49D
ROC5W28_X54K5TT30A
ROC6W28_X54K5TT30B
ROC7W28_X54K5TT30C

Depletion Voltage is -48 and suggested operational voltage is -88
Ibias_DAC, Ibias_DAC Data 148 140 134 150 146 136 130 144
Vana, VanaData 135 134 140 135 138 127 127 135
CalDelData and plots6877848981928966
VthrCompData and plots7770817372827476
TestDdata ,TestD Plots00000000
LightData ,Light Plots00000000
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD

Comment (if any): All good.

This Device have been tested 0Times prior to this one and here are the links to the previous tests:

End testing time: 12:01 PM