P_2x4T_082_A-1

Production testing

Date:1/15/2007

Operator: gino Bolla

start testing time:1:27 PM

Sensor: S_2x4T_08, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W32_XA4K5NT53C
ROC1W32_XA4K5NT53B
ROC2W32_XA4K5NT53A
ROC3W32_XA4K5NT52D
ROC4W32_XA4K5NT32D
ROC5W32_XA4K5NT33A
ROC6W32_XA4K5NT34D
ROC7W32_XA4K5NT35B

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -90
Ibias_DAC, Ibias_DAC Data 144 142 144 144 140 150 140 122
Vana, VanaData 128 141 145 137 126 143 136 126
TestDdata ,TestD Plots00000010
LightData ,Light Plots00000000
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD

Comment (if any): GOOD

This Device have been tested 1Times prior to this one and here are the links to the previous tests:

P_2x4T_082_A.html,

End testing time: 1:34 PM