Sensor: S_2x4T_03, Data for leakage current measurement , and plot on overall it is a GOOD sensor
| ROC | ROC wafer | Label |
|---|---|---|
| ROC0 | XE4KFET | 14A |
| ROC1 | XE4KFET | 05C |
| ROC2 | XE4KFET | 15A |
| ROC3 | XE4KFET | 16D |
| ROC4 | XE4KFET | 12C |
| ROC5 | XE4KFET | 17D |
| ROC6 | XE4KFET | 14C |
| ROC7 | XE4KFET | 06A |
| Ibias_DAC, Ibias_DAC Data | 138 | 132 | 150 | 138 | 124 | 128 | 136 | 132 |
| Vana, VanaData | 141 | 135 | 140 | 120 | 129 | 138 | 138 | 140 |
| CalDelData and plots | 78 | 91 | 73 | 88 | 85 | 86 | 73 | 83 |
| VthrCompData and plots | 79 | 70 | 85 | 63 | 76 | 72 | 76 | 83 | Depletion Voltage is -54 and suggested operational voltage is -94
| TestDdata ,TestD Plots | 3 | 0 | 0 | 2 | 0 | 0 | 0 | 1 |
| LightData ,Light Plots | 1 | 0 | 12 | 1 | 0 | 0 | 1 | 0 |
| Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
| Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any): good
This Device have been tested 8Times prior to this one and here are the links to the previous tests:End testing time: 9:10 AM