P_2x4B_156_A-1

Production testing

Date:2/1/2007

Operator: Isaac Childres

start testing time:3:03 PM

Sensor: S_2x4B_15, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W28_X54K5TT66B
ROC1W28_X54K5TT66A
ROC2W28_X54K5TT65D
ROC3W28_X54K5TT64D
ROC4W28_X54K5TT43D
ROC5W28_X54K5TT44B
ROC6W28_X54K5TT45A
ROC7W28_X54K5TT45B

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 142 128 146 146 146 144 146 132
Vana, VanaData 123 122 124 144 140 128 140 140
TestDdata ,TestD Plots10000000
LightData ,Light Plots10000000
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD GOOD GOOD GOOD

Comment (if any): Good.

This Device have been tested 1Times prior to this one and here are the links to the previous tests:

P_2x4B_156_A.html,

End testing time: 3:10 PM