Sensor: S_2x4B_11, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | W30_X74K5RT | 20B |
ROC1 | W30_X74K5RT | 20A |
ROC2 | W30_X74K5RT | 39D |
ROC3 | W30_X74K5RT | 39C |
ROC4 | W30_X74K5RT | 16B |
ROC5 | W30_X74K5RT | 16C |
ROC6 | W30_X74K5RT | 16D |
ROC7 | W30_X74K5RT | 17C |
Ibias_DAC, Ibias_DAC Data | 142 | 142 | 138 | 144 | 138 | 144 | 124 | 122 |
Vana, VanaData | 128 | 137 | 126 | 132 | 129 | 135 | 123 | 127 |
CalDelData and plots | 76 | 82 | 79 | 78 | 73 | 72 | 82 | 97 |
VthrCompData and plots | 80 | 88 | 81 | 84 | 71 | 73 | 69 | 69 | Depletion Voltage is -48 and suggested operational voltage is -88
TestDdata ,TestD Plots | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
LightData ,Light Plots | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any): Good.
This Device have been tested 0Times prior to this one and here are the links to the previous tests:End testing time: 2:02 PM