Sensor: S_2x3T_18, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | KBNG0QT | 46B |
ROC1 | KBNG0QT | 56D |
ROC2 | KBNG0QT | 46A |
ROC3 | KBNG0QT | 47B |
ROC4 | KBNG0QT | 47D |
ROC5 | KBNG0QT | 37B |
Ibias_DAC, Ibias_DAC Data | 158 | 150 | 148 | 158 | 154 | 150 |
Vana, VanaData | 142 | 144 | 129 | 139 | 144 | 139 |
CalDelData and plots | 67 | 81 | 73 | 77 | 77 | 81 |
VthrCompData and plots | 87 | 83 | 76 | 77 | 80 | 76 | Depletion Voltage is -76 and suggested operational voltage is -116
TestDdata ,TestD Plots | 0 | 5 | 0 | 0 | 0 | 2 |
LightData ,Light Plots | 1 | 0 | 0 | 0 | 0 | 0 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD | GOOD |
Noise MAP at VMAX
Efficiency MAP
EXTRA DACs for NOISE
VHldDe | 90 | 95 | 100 | 90 | 95 | 95 |
Vsf | 145 | 145 | 135 | 140 | 145 | 140 |
VoffsetOp | 80 | 95 | 85 | 105 | 75 | 95 |
VIbias_PH | 105 | 95 | 100 | 100 | 100 | 95 |
Comment (if any):
This Device have been tested 7Times prior to this one and here are the links to the previous tests:End testing time: 5:03 PM