P_2x3T_115_A

Production testing

Date:3/12/2007

Operator: Gino Bolla

start testing time:12:51 PM

Sensor: S_2x3T_11, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W34_XA4K3PT52C
ROC1W34_XA4K3PT52A
ROC2W34_XA4K3PT51D
ROC3W34_XA4K3PT48D
ROC4W34_XA4K3PT49A
ROC5W34_XA4K3PT49B

Depletion Voltage is -44 and suggested operational voltage is -84
Ibias_DAC, Ibias_DAC Data 144 152 142 134 152 126
Vana, VanaData 123 139 140 127 151 123
CalDelData and plots1009283907278
VthrCompData and plots708373758880
TestDdata ,TestD Plots000000
LightData ,Light Plots000000
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD GOOD

Noise MAP

[IMAGE] of

Efficiency MAP

[IMAGE] of

EXTRA DACs for NOISE

VHldDe1409095140105165
Vsf135140140135145135
VoffsetOp80115809014075
VIbias_PH100100100105100105
ROC0 NOISE[IMAGE] of [IMAGE] of MEAN = 4.433174

SIGMA = 0.348882
ROC1 NOISE[IMAGE] of [IMAGE] of MEAN = 4.243536

SIGMA = 0.341552
ROC2 NOISE[IMAGE] of [IMAGE] of MEAN = 4.665449

SIGMA = 0.363335
ROC3 NOISE[IMAGE] of [IMAGE] of MEAN = 4.719008

SIGMA = 0.364430
ROC4 NOISE[IMAGE] of [IMAGE] of MEAN = 3.784958

SIGMA = 0.276838
ROC5 NOISE[IMAGE] of [IMAGE] of MEAN = 5.512006

SIGMA = 0.428600

Comment (if any): GOOD

This Device have been tested 0Times prior to this one and here are the links to the previous tests:

End testing time: 1:10 PM