P_2x3B_901_C-4

Production testing

Date:10/2/2007

Operator: Gino Bolla

start testing time:9:18 AM

Sensor: S_2x3B_90, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0UNKNOWNUNKNOWN
ROC1UNKNOWNUNKNOWN
ROC2UNKNOWNUNKNOWN
ROC3UNKNOWNUNKNOWN
ROC4UNKNOWNUNKNOWN
ROC5UNKNOWNUNKNOWN

Depletion Voltage is -254 and suggested operational voltage is -294
Ibias_DAC, Ibias_DAC Data 154 158 158 156 158 162
Vana, VanaData 113 151 144 144 157 141
CalDelData and plots888573808076
VthrCompData and plots747380778777
TestDdata ,TestD Plots230303316429248275
LightData ,Light Plots241264326447265287
Pass/Fail TestD BAD BAD BAD BAD BAD BAD
Pass/Fail LIGHT BAD BAD BAD BAD BAD BAD

Noise MAP at VMAX

[IMAGE] of

Efficiency MAP

[IMAGE] of

EXTRA DACs for NOISE

VHldDe140859012090110
Vsf130145145145155140
VoffsetOp859510580110105
VIbias_PH10095100100100100
ROC0 NOISE[IMAGE] of [IMAGE] of MEAN = 4.497370

SIGMA = 0.362826
ROC1 NOISE[IMAGE] of [IMAGE] of MEAN = 4.018536

SIGMA = 0.364016
ROC2 NOISE[IMAGE] of [IMAGE] of MEAN = 4.279797

SIGMA = 0.369702
ROC3 NOISE[IMAGE] of [IMAGE] of MEAN = 4.906693

SIGMA = 0.392897
ROC4 NOISE[IMAGE] of [IMAGE] of MEAN = 4.361238

SIGMA = 0.368592
ROC5 NOISE[IMAGE] of [IMAGE] of MEAN = 4.077554

SIGMA = 0.313247

Comment (if any):

This Device have been tested 4Times prior to this one and here are the links to the previous tests:

P_2x3B_901_C-1.html,

P_2x3B_901_C-2.html,

P_2x3B_901_C-3.html,

P_2x3B_901_C.html,

End testing time: 9:47 AM