Sensor: S_2x3B_07, Data for leakage current measurement , and plot on overall it is a GOOD sensor
| ROC | ROC wafer | Label |
|---|---|---|
| ROC0 | W13_XX4JPAT | 15C |
| ROC1 | W13_XX4JPAT | 03C |
| ROC2 | W13_XX4JPAT | 15A |
| ROC3 | W13_XX4JPAT | 17C |
| ROC4 | W13_XX4JPAT | 17D |
| ROC5 | W13_XX4JPAT | 18A |
| Ibias_DAC, Ibias_DAC Data | 142 | 134 | 134 | 138 | 124 | 146 |
| Vana, VanaData | 128 | 127 | 131 | 117 | 105 | 124 | FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
| TestDdata ,TestD Plots | 2 | 2 | 129 | 806 | 1 | 1 |
| LightData ,Light Plots | 0 | 0 | 0 | 941 | 0 | 0 |
| Pass/Fail TestD | GOOD | GOOD | BAD | BAD | GOOD | GOOD |
| Pass/Fail LIGHT | GOOD | GOOD | GOOD | BAD | GOOD | GOOD |
Comment (if any):
This Device have been tested 2Times prior to this one and here are the links to the previous tests:End testing time: 4:25 PM