P_2x3B_067_A-2

Production testing

Date:2/19/2007

Operator: Gino Bolla

start testing time:3:20 PM

Sensor: S_2x3B_06, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W29_X64K5ST05C
ROC1W29_X64K5ST05B
ROC2W29_X64K5ST04D
ROC3W33_XC4K5LT67C
ROC4W33_XC4K5LT67D
ROC5W33_XC4K5LT68A

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 118 138 132 140 132 142
Vana, VanaData 135 134 123 148 137 135