Sensor: S_1x5R_16, Data for leakage current measurement , and plot on overall it is a GOOD sensor
| ROC | ROC wafer | Label |
|---|---|---|
| ROC0 | KNN0GDT | 14D |
| ROC1 | KNN0GDT | 04B |
| ROC2 | KNN0GDT | 74A |
| ROC3 | KNN0GDT | 74C |
| ROC4 | KNN0GDT | 18C |
| Ibias_DAC, Ibias_DAC Data | 134 | 144 | 138 | 148 | 156 |
| Vana, VanaData | 134 | 143 | 134 | 134 | 143 |
| CalDelData and plots | 84 | 77 | 90 | 68 | 72 |
| VthrCompData and plots | 86 | 75 | 73 | 79 | 78 | Depletion Voltage is -46 and suggested operational voltage is -86
| TestDdata ,TestD Plots | 0 | 0 | 0 | 0 | 1 |
| LightData ,Light Plots | 0 | 0 | 0 | 0 | 1 |
| Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD |
| Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD |
Noise MAP
Efficiency MAP
EXTRA DACs for NOISE
| VHldDe | 115 | 85 | 115 | 115 | 100 |
| Vsf | 140 | 145 | 140 | 140 | 140 |
| VoffsetOp | 85 | 95 | 75 | 85 | 95 |
| VIbias_PH | 95 | 100 | 105 | 100 | 100 |
Comment (if any): good
This Device have been tested 0Times prior to this one and here are the links to the previous tests:End testing time: 10:55 AM