Sensor: S_1x5R_14, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | W31_X44K5UT | 58B |
ROC1 | W31_X44K5UT | 58A |
ROC2 | W31_X44K5UT | 57D |
ROC3 | W31_X44K5UT | 57C |
ROC4 | W31_X44K5UT | 57A |
Ibias_DAC, Ibias_DAC Data | 138 | 130 | 130 | 138 | 136 |
Vana, VanaData | 123 | 143 | 129 | 133 | 134 | FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
TestDdata ,TestD Plots | 0 | 0 | 0 | 0 | 0 |
LightData ,Light Plots | 0 | 0 | 0 | 0 | 0 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | GOOD | GOOD | GOOD |
Comment (if any): Good.
This Device have been tested 1Times prior to this one and here are the links to the previous tests:End testing time: 1:48 PM