P_1x5R_149_A-1

Production testing

Date:2/2/2007

Operator: Isaac Childres

start testing time:1:43 PM

Sensor: S_1x5R_14, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W31_X44K5UT58B
ROC1W31_X44K5UT58A
ROC2W31_X44K5UT57D
ROC3W31_X44K5UT57C
ROC4W31_X44K5UT57A

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 138 130 130 138 136
Vana, VanaData 123 143 129 133 134
TestDdata ,TestD Plots00000
LightData ,Light Plots00000
Pass/Fail TestD GOOD GOOD GOOD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD GOOD GOOD GOOD

Comment (if any): Good.

This Device have been tested 1Times prior to this one and here are the links to the previous tests:

P_1x5R_149_A.html,

End testing time: 1:48 PM