Sensor: S_1x5R_04, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | XF4K3JT | 15B |
ROC1 | XF4K3JT | 16A |
ROC2 | XF4K3JT | 23D |
ROC3 | XF4K3JT | 17A |
ROC4 | XF4K3JT | 17B |
Ibias_DAC, Ibias_DAC Data | 128 | 138 | 123 | 139 | 138 |
Vana, VanaData | 127 | 134 | 108 | 133 | 134 |
CalDelData and plots | 81 | 74 | 87 | 77 | 87 |
VthrCompData and plots | 70 | 78 | 73 | 79 | 66 | Depletion Voltage is -56 and suggested operational voltage is -96
TestDdata ,TestD Plots | 0 | 6 | 4 | 0 | 8 |
LightData ,Light Plots | 0 | 23 | 161 | 0 | 8 |
Pass/Fail TestD | GOOD | GOOD | GOOD | GOOD | GOOD |
Pass/Fail LIGHT | GOOD | GOOD | BAD | GOOD | GOOD |
Comment (if any): Laser worked this time. Bad bumps still the same.
This Device have been tested 2Times prior to this one and here are the links to the previous tests:End testing time: 2:43 PM