P_1x2R_088_A

Production testing

Date:11/27/2006

Operator: Gino Bolla

start testing time:11:39 AM

Sensor: S_1x2R_08, Data for leakage current measurement , and plot on overall it is a BAD sensor
ROCROC waferLabel
ROC0W21_XA4KFIT62A
ROC1W21_XA4KFIT05C

Depletion Voltage is -46 and suggested operational voltage is -86
Ibias_DAC, Ibias_DAC Data 135 125
Vana, VanaData 118 115
CalDelData and plots8086
VthrCompData and plots7484
TestDdata ,TestD Plots4528
LightData ,Light Plots00
Pass/Fail TestD BAD GOOD
Pass/Fail LIGHT GOOD GOOD

Comment (if any): Many DEAD CHANNELS on both ROCs like other devices in this batch.

This Device have been tested 0Times prior to this one and here are the links to the previous tests:

End testing time: 11:52 AM