Sensor: S_1x2L_15, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROC | ROC wafer | Label |
---|---|---|
ROC0 | X94KFJT | 20D |
ROC1 | X94KFJT | 21C |
Ibias_DAC, Ibias_DAC Data | 122 | 130 |
Vana, VanaData | 125 | 118 |
CalDelData and plots | 90 | 84 |
VthrCompData and plots | 62 | 76 | Depletion Voltage is -50 and suggested operational voltage is -90
TestDdata ,TestD Plots | 582 | 2 |