Date:11/27/2006

Operator: Gino Bolla

start testing time:11:56 AM

Sensor: S_1x2L_12, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W19_XN4K38T65C
ROC1W19_XN4K38T64C

Depletion Voltage is -10 and suggested operational voltage is -50
Ibias_DAC, Ibias_DAC Data 135 130
Vana, VanaData 127 117
CalDelData and plots9486
VthrCompData and plots7175
TestDdata ,TestD Plots00
LightData ,Light Plots00
Pass/Fail TestD GOOD GOOD
Pass/Fail LIGHT GOOD GOOD

Comment (if any): To be redone the laser did NOT work well.

This Device have been tested 0Times prior to this one and here are the links to the previous tests:

End testing time: 12:07 PM