P_1x2L_067_A-2

Production testing

Date:2/19/2007

Operator: Gino Bolla

start testing time:2:30 PM

Sensor: S_1x2L_06, Data for leakage current measurement , and plot on overall it is a GOOD sensor
ROCROC waferLabel
ROC0W29_X64K5ST03B
ROC1W29_X64K5ST03A

FIXED (not measured) Depletion Voltage is -50 and FIXED (not measured) suggested operational voltage is -150
Ibias_DAC, Ibias_DAC Data 146 136
Vana, VanaData 141 145